Molecule_types <num_types> <name> <number> [fixed] ... <name> <number> [fixed]
Which molecules to simulate. <num_types>
is the number of molecule
types. This keyword must be followed by <num_types>
lines each of
which contains at least two parameters: <name>
and <number>
<name>
- name of the molecule. File <name>.mmol
, describing
the molecular structure and the force field parameters, must be
present in directory specified by parameter Path_DB
.
<number>
- number of molecules of this type.
``fixed'' - Option ``fixed'' signals that these molecules are fixed and will not move in the MD procedure.
This keyword and its parameters (except ``fixed'') are compulsory
PBC <type>
Type of periodic boundary conditions
<type>
may be:
rect
- rectangular (default)
hexa
- hexagonal
octa
- truncated octahedron
Box <box-x> <box-y> <box-z>
Specifies simulation box size (in Å). In case of hexagonal boundary
conditions, only box-x
and box-z
have a meaning.
For octahedral boundary conditions only <box-x>
has a meaning.
The keyword cannot be used simultaneously with ``Density''
Density <value>
Setup initial density. <value>
is density in . This option
cannot be used simultaneously with setting up box sizes. In case of
rectangular periodic boundary conditions, a cubic cell is implied. Zero
density implies ``vacuum simulation'' regime with the box size automatically
set to 1000 Å
El_field <ampl> <freq>
Put the system in a homogeneous time-dependent electrostatic field
(11) |
where <ampl>
is given in and <freq>
in .